Welcome, Guest LOG IN or REGISTER

BestgasTech Support:  (+86) 027-85568699, Email: ava.wong@hkxytech.com

Cart

Honeywell SPXCDDMK Duct mounting kit

Sale!

Honeywell SPXCDDMK Duct mounting kit

$350.00 $287.00

New and Original! Contact us for more details and accurate offer!

Compare

Share this product

Honeywell SPXCDALMCX XCD Gas Detector

Sensepoint XCD

SPXCDASMFX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMRX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMPX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMO1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDASMHX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDASMCX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDASMNX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDASMG1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDASMB1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDASMB2
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDALMFX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMRX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMPX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMO1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDALMHX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDALMCX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDALMNX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDALMG1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDALMB1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDALMB2
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection

UL/c-UL/INMETRO Approvals (316SS)
SPXCDUSNFX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNRX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNPX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNO1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDUSNHX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDUSNCX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDUSNNX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDUSNG1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDUSNB1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDUSNB2
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection

UL/c-UL/INMETRO Approvals (LM25)
SPXCDULNFX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNRX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNPX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNO1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDULNHX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDULNCX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDULNNX
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDULNG1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDULNB1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDULNB2
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDASMFXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMRXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMPXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDASMO1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDASMHXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDASMCXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDASMNXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDASMG1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDASMB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDASMB2M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDALMFXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMRXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMPXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDALMO1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDALMHXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDALMCXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDALMNXM
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDALMG1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDALMB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDALMB2M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDUSNFXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNRXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNPXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDUSNO1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDUSNHXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDUSNCXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDUSNNXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDUSNG1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDUSNB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDUSNB2M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDULNFXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNRXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNPXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
SPXCDULNO1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
SPXCDULNHXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
SPXCDULNCXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
SPXCDULNNXM
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
SPXCDULNG1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
SPXCDULNB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDULNB2M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v, includes nylon weather protection
SPXCDXSFXSS
Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSRXSS
Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSO1SS
Oxygen 25.0% v/v only
SPXCDXSHXSS
Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)
SPXCDXSCXSS
Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
SPXCDXSNXSS
Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)
SPXCDXSG1SS
Hydrogen 0-1000ppm only
SPXCDXSPXSS
Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSB1SS
Carbon Dioxide IR 0-2.00% v/v only
SPXCDXSB2SS
Carbon Dioxide IR 0-5.00% v/v only
SPXCDALMTXO
XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXT
XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXF
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDASMTXO
XCD O2 Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection
SPXCDASMTXT
XCD Toxic Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection
SPXCDASMTXF
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nylon weather protection
SPXCDALMTXOM
XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXTM
XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDALMTXFM
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nylon weather protection
SPXCDASMTXOM
XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS
SPXCDASMTXTM
XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS
SPXCDASMTXFM
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS
SPXCDULNTXO
XCD O2 Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXT
XCD Toxic Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXF
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection
SPXCDUSNTXO
XCD O2 Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXT
XCD Toxic Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXF
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDULNTXOM
XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXTM
XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection
SPXCDULNTXFM
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted LM25, includes nylon weather protection, includes nylon weather protection
SPXCDUSNTXOM
XCD O2 Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXTM
XCD Toxic Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDUSNTXFM
XCD IR & Flammable Transmitter (without sensor), 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4″ NPT entries, painted 316SS, includes nylon weather protection
SPXCDASMRFD
XCD RFD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
SPXCDALMRFD
XCD RFD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
SPXCDUSNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAus/INMETRO, 3 x 3/4″ NPT entries, painted 316SS
SPXCDULNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAus/INMETRO, 3 x 3/4″ NPT entries, painted LM25
SPXCDXSRFXSS
XCD RFD remote plug-in sensor and socket, includes catalytic sensor cartridge 0 to 100%LEL
SPXCDXSRRXSS
XCD RFD remote plug-in sensor and socket, includes infrared methane sensor cartridge 0 to 100%LEL
SPXCDXSRPXSS
XCD RFD remote plug-in sensor and socket, includes infrared propane sensor cartridge 0 to 100%LEL
SPXCDXSRB1SS
XCD RFD remote plug-in sensor and socket, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v
SPXCDXSRB2SS
XCD RFD remote plug-in sensor and socket, includes infrared carbon dioxide sensor cartridge 0 to 5.0% v/v
SPXCDASMRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
SPXCDALMRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
SPXCDUSNRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, cCSAus/INMETRO, 3 x 3/4″ NPT entries, painted 316SS
SPXCDULNRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, cCSAus/INMETRO, 3 x 3/4″ NPT entries, painted LM25
SPXCDXSFXSS
Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSRXSS
Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSPXSS
Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
SPXCDXSB1SS
Carbon Dioxide IR 0-2.00% v/v only
SPXCDASMTX4
XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
SPXCDALMTX4
XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
SPXCDUSNTX4
XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4″ NPT entries, painted 316SS
SPXCDULNTX4
XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4″ NPT entries, painted LM25
SPXCDASMTX4M
XCD RTD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
SPXCDALMTX4M
XCD RTD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
SPXCDUSNTX4M
XCD RTD Transmitter, 4 to 20 mA and Modbus output, cCSAus, 3 x 3/4″ NPT entries, painted 316SS
SPXCDULNTX4M
XCD RTD Transmitter, 4 to 20 mA and Modbus output, cCSAus, 3 x 3/4″ NPT entries, painted LM25
S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
SPXCDCC Collecting cone for use with lighter than air gases
SPXCDDMK Duct mounting kit
SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
SPXCDSDP Sunshade / Deluge Protection
00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm – 3 X 20mm Entries – ATEX Approved
90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle
90068-C-8290 PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter
90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter
90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter
ADU300429 Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2″NPT (female)
RDU303029 Reducer, ATEX, Ex d e, 316SS, 3/4″NPT (male) to 1/2″NPT (female)
PDU300400 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug
PDU303000 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4″ NPT Blanking Plug
X4S-2006662 Field Device Tag Label (Based on Drawing Number 90084-C-7013).

Additional information

Weight3000 g
Dimensions20 × 20 × 20 cm

Reviews

There are no reviews yet.

Be the first to review “Honeywell SPXCDDMK Duct mounting kit”